02/16 MN05013001Z EN
EM01 NEN MST *
*** ***
>FT
3.0s
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
Function block: external device monitoring , No. 1
EM01
Enable: None required
NEN
Operating mode: Manual start
MST
Monitoring time: 3.0 seconds
>FT
The parameters consist of the following:
Enable
The Enable parameter specifies whether an external function
block enable is required. Further information can be found at
section "Enable parameter, EN enable coil" on page 345.
Mode
Function, parameterisation in the func-
parameter
tion block
External enable required
EN
No external enable required
NEN
This parameter is factory set to NEN, the function block is
active without an external enable.
EM, feedback circuit-
monitoring
351