Deleting Function Blocks - Eaton easySafety Manual

Control relay
Table of Contents

Advertisement

Wiring with easySafety
AR01 ADD
CP10
T 18 ?X
L:002
170

Deleting function blocks

Requirement: The easySafety device must be in STOP mode.
Move the cursor in the circuit diagram to all the contact
X
fields and the coil field in which the function block to be
deleted is used and press DEL each time. In the following
example, delete first of all contact field ES01I1, then
contact field ES01RE and finally coil field ES01QS. The
grey fields shows the currently flashing cursor position.
IS07------------Ä ES01I1
IS08------------Ä ES01RE
ES01QS----------Ä QS02
L: 1 C:1 B:7704
Figure 69: Deleting the safety function block ES
Deleting standard function blocks from the function
block list
In order to prevent accidental deletion, a standard function
block continues to be managed in the function block list,
even if it was already removed in the standard circuit
diagram. To delete the standard function block permanently
and therefore to free up more memory, you must remove it
from the function block list.
Open the function block list via STANDARD -> PROGRAM
X
+
-> FUNCTION RELAYS.
+
Select the standard function block to be deleted in the
X
-
function block list, in this case CP10.
B:5430
Press the DEL button.
X
The standard function block is removed from the function
block list.
Press ESC in order to save the function block with the
X
deleted standard function block.
Answer the subsequent SAVE prompt with OK.