Eaton easySafety Manual page 518

Control relay
Table of Contents

Advertisement

Safety function blocks
Status number
Hexadecimal (0–F)
0000
2001
2003
2004
2009
8010
F007
F008
F009
F00A
F013
514
Outputs
The actual value output QV: Indicates the actual value of the
rotation frequency with a tolerance of less than 3 percent..
Diagnostics output DG: Provides information the states of
the function block. It is evaluated in the standard circuit
diagram e. g. with the diagnostics function block.
Parameters
QV:
DG:
Table 23:
Diagnostics-/-Error codes
Plain text
decimal (0-9)
0000
No Enable.
8193
Enable issued, wait for safe activation via ZM..SA input.
8195
Waiting for rising edge at Reset.
8196
Waiting for falling edge at Reset.
8201
Measurement started.
32784
Standstill detected (QS = 1).
61447
Error: Both channels on Low (open circuit).
61448
Error: Frequency measuring range exceeded (>1200 Hz).
61449
Error: Different input frequencies.
61450
Error: No pulses on one channel.
61459
Error: Reset operated on function block startup.
Further information on these outputs is provided in section
"Common features", page 348.
02/16 MN05013001Z EN
Function, parameterisation in the func-
tion block
Rotation frequency actual value: 2 - 50 Hz
Diagnostics: double worda table 23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents