Standard function blocks
304
Parameter display
The display of the parameters during operation can be
disabled. Further information can be found in section
"Parameter assignment from the standard circuit diagram"
on page 161.
Parameters
Function
Parameters are displayed
+
Parameters are not displayed
-
This parameter is factory set to +.
Inputs
In DW mode you assign function block inputs >I1 and >I2
with the values that are to be read into the shift register.
Parameters
Function
Input value forwards:
>I1
-2147483648 - +2147483647
Input value backwards:
>I2
-2147483648 - +2147483647
The inputs can have the following operands:
• Constant.
• Markers MD, MW, MB.
• Output
QV> of a different function block.
...