Eaton easySafety Manual page 455

Control relay
Table of Contents

Advertisement

02/16 MN05013001Z EN
OS01 NEN *** *
*** ***
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
Function block: operating mode switch, number 01
OS01
Enable: none required
NEN
The parameters consist of the following:
Enable
The Enable parameter specifies whether an external function
block enable is required. Further information can be found at
section "Enable parameter, EN enable coil" on page 345.
Parameters
Function, parameterisation in the func-
tion block
External enable required
EN
No external enable required
NEN
This parameter is factory set to NEN, the function block is
active without an external enable.
OS, operating mode selector
switch
451

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents