Mx, Data Multiplexer - Eaton easySafety Manual

Control relay
Table of Contents

Advertisement

Standard function blocks

MX, data multiplexer

276
The data multiplexer function block allows you to select a
value from eight input values MX..I1 to MX..I8 as if using a
mode selector switch. The function block provides this value
after transferring it to its output MX..QV.
easySafety allows the use of up to 16 data multiplexers.
Function block
MX...
MultipleXer
a
EN
b
DW
>K
DW
>I1
DW
>I2
DW
>I3
DW
>I4
c
DW
>I5
DW
>I6
DW
>I7
DW
>I8
Figure 126: Data multiplexer function block
a Coil MX..EN: Enables the operation of the function block.
b Input MX..K: Sets the channel number.
c Inputs MX..I1 to MX..I8: Input channels I1 to I8.
d Contact MX..E1: Closes if an invalid channel was set.
e Output MX..QV: Supplies the selected input value.
02/16 MN05013001Z EN
E1
d
QV>
DW
e