02/16 MN05013001Z EN
FS01 NEN *** *
*** 4CH
>ED OFF
Parameters
When using the function block in the circuit diagram for the
first time, use OK to automatically enter the general display
of function block parameters, as shown in the figure on the
left. Enter the function block settings here. The display
contains the following elements:
Safety foot switch function block, No. 01
FS01
Enable: None required
NEN
Number of switch channels: 4 channels
4CH
Enable time: OFF (no monitoring time active).
>ED
The parameters consist of the following:
Enable
The Enable parameter specifies whether an external function
block enable is required. Further information can be found at
section "Enable parameter, EN enable coil" on page 345.
Parameters
Function, parameterisation in the func-
tion block
External enable required
EN
No external enable required
NEN
This parameter is factory set to NEN, the function block is
active without an external enable.
Evaluation
The parameter sets the function block for monitoring foot
switches with two or 4 break contacts.
Parameters
Function, parameterisation in the func-
tion block
2-channel evaluation
2CH
4-channel evaluation
4CH
easySafety is defined with a default setting for 4-channel
evaluation.
FS, safety foot switch
385