Eaton easySafety Manual page 624

Control relay
Table of Contents

Advertisement

easySafety internal
Status number
Hexadecimal (0–F)
801A
801B
801C
8024
8027
802A
802B
802C
802D
802E
8034
8037
803A
803B
803C
803D
803E
F001
F002
F003
F004
F005
F006
F007
620
Plain text
decimal (0-9)
32794
Waiting until feedback circuit open.
32795
Check test signal T1 for short circuit.
32796
Check test signal T2 for short circuit.
32804
Muting state 4 in mode 2P
32807
Muting state 7 in mode 2P
32810
Operating mode 1 selected (Q1 = 1).
32811
Operating mode 2 selected (Q2 = 1).
32812
Operating mode 3 selected (Q3 = 1).
32813
Operating mode 4 selected (Q4 = 1).
32814
Operating mode 5 selected (Q5 = 1).
32820
Muting state 4 in mode 2S
32823
Muting state 7 in mode 2S
32826
Operating mode 1 fixed
32827
Operating mode 2 fixed
32828
Operating mode 3 fixed
32829
Operating mode 4 fixed
32830
Operating mode 5 fixed
61441
Error: Discrepancy time expired.
61442
Error: Enable duration exceeded.
61443
Error: Muting duration exceeded.
61444
Error: Synchronization duration exceeded.
61445
Error: Clearing duration exceeded.
61446
Error: Second pushbutton pressed too late (> 500
ms).
61447
Error: Both channels on Low (open circuit).
02/16 MN05013001Z EN
(Q1 = 1).
(Q2 = 1).
(Q3 = 1).
(Q4 = 1).
(Q5 = 1).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents