Ä Om01Sa; Om01Qs; Is12; The Enable Contact Of The Overspeed Monitoring Function - Eaton easySafety Manual

Control relay
Table of Contents

Advertisement

Safety function blocks
+24 V
0 V
-B1
-F1
S 1A
+24V 0V
0V
-K1
DC 24 V
ES4P-221-DRXD1
FS01 NEN *** *
*** 2CH
>ED
3.0min
392
L+
L+
-B2
A
A
L-
L-
IS1
IS2
IS3
IS4
IS5
IS6
Input 14 x DC
DEL
P2
P1
P4
ESC
Output 4x Relay / 6A
1
2 1
2 1
QS1
QS2
QS3
Figure 196:
The circuit diagram in easySafety has only five rungs:
-------------------------------Ä OM01SA
OM01QS---IS08------------------Ä FS01SA
IS11---------------------------Ä FS01I1
IS12---------------------------Ä FS01I2
FS01QS-------------------------Ä MS05
Figure 197:

The enable contact of the overspeed monitoring function

block OM01QS and the key switch S1 at IS08 switch coil
FS01SA. The test signals T3 and T4 supply the foot switch
S11 connected to the device terminals IS12 and IS2.
The parameters for the enable stay in the default setting, you
set the number of channels to 2 (2CH) and the maximum
permissible enable time to 3.0 minutes.
02/16 MN05013001Z EN
0
I
-S1
IS7
IS8
IS9 IS10 IS11 IS12 IS13 IS14
ea ySafety
ALT
P3
OK
4x Test Signal
2 1
2
QS4
T1
T2
T3
Foot switch example: Electrical circuit diagram
Foot switch example: Circuit diagram in
easySafety
NET
T4
0
1
2
A1
A2
B1
B2
-S2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents