Safety function blocks
414
Muting sensors
The setting of this parameter depends on the arrangement
of muting sensors and the muting procedure selected.
Parameters
Function, parameterisation in the func-
tion block
Use of 2 sensors A1 and A2 for parallel muting,
2P
crossed arrangement (default settings)
Use of 2 sensors A1 and A2 for serial muting,
2S
adjacent arrangement
Use of 4 sensors A1, A2 and B1, B2 for parallel
4P
muting, opposing arrangement
Use of 4 sensors A1, A2 and B1, B2 for sequen-
4S
tial muting, adjacent arrangement
Discrepancy time
The discrepancy time LM..DT can be set when activated for
2-channel light curtain monitoring.
Parameters
Function, parameterisation in the func-
tion block
OFF; 0.5 - 3.0 s; adjustable in increments of
>DT
g? ? 5 s
easySafety is factory set with a discrepancy time of 3.0 s.
02/16 MN05013001Z EN