Eaton easySafety Manual page 418

Control relay
Table of Contents

Advertisement

Safety function blocks
414
Muting sensors
The setting of this parameter depends on the arrangement
of muting sensors and the muting procedure selected.
Parameters
Function, parameterisation in the func-
tion block
Use of 2 sensors A1 and A2 for parallel muting,
2P
crossed arrangement (default settings)
Use of 2 sensors A1 and A2 for serial muting,
2S
adjacent arrangement
Use of 4 sensors A1, A2 and B1, B2 for parallel
4P
muting, opposing arrangement
Use of 4 sensors A1, A2 and B1, B2 for sequen-
4S
tial muting, adjacent arrangement
Discrepancy time
The discrepancy time LM..DT can be set when activated for
2-channel light curtain monitoring.
Parameters
Function, parameterisation in the func-
tion block
OFF; 0.5 - 3.0 s; adjustable in increments of
>DT
g? ? 5 s
easySafety is factory set with a discrepancy time of 3.0 s.
02/16 MN05013001Z EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents