Eaton easySafety Manual page 207

Control relay
Table of Contents

Advertisement

02/16 MN05013001Z EN
Comparison
Value
range 1
marker
range 1
(dec./binary)
MB60
45/
00101101
Example 3: Initialisation of marker blocks, transfer of a
range to a different format.
The value of marker byte MB60 is to be transferred to MD80
and MD81.
• Parameters of function block BT01:
– Source range:
– Destination range:
– Number of bytes:
h
The transfer is in byte format. MD80 has 4 bytes and
MD81 has 4 bytes, which means that >NO has the value
8.
Comparison
range 2
MD80
(Byte 1, LSB)
MD80
(Byte 2)
MD80
(Byte 3)
MD80
(Byte 4, MSB)
MD81
(Byte 1, LSB)
MD81
(Byte 2)
MD81
(Byte 3)
MD81
(Byte 4, MSB)
BT, data block transfer
>I1 MB60
>I2 MD80
>NO
Value of marker range 2 (decimal/binary)
757935405/
00101101001011010010110100101101
757935405/
00101101001011010010110100101101
757935405/
00101101001011010010110100101101
757935405/
00101101001011010010110100101101
757935405/
00101101001011010010110100101101
757935405/
00101101001011010010110100101101
757935405/
00101100010110110010110100101101
757935405/
00101101001011010010110100101101
8
203