Analog Outputs - Siemens sinamics dcp Operating Instructions Manual

Dc/dc power converter
Hide thumbs Also See for sinamics dcp:
Table of Contents

Advertisement

Operation
8.2 Inputs/outputs
AI 2
AI 3, AI 4, AI 5, AI 6
Function diagrams
2075
2080
2085
2090
8.2.4

Analog outputs

See function diagram 2095 in the SINAMICS DCP List Manual.
134
Differential input
Voltage input -10 to +10 V
Hardware input filter: T = 1 ms
Integrating measuring procedure. Averaging time = 1 ms. The average value determined during
this time is provided in BICO format.
Differential inputs
Voltage inputs -10 to +10 V
Hardware input filter: T = 100 µs
Sampling measuring procedure. Sampling time = 250 µs. The mean value taken from four sam-
pling values is provided in BICO format.
Analog input AI 0
Analog inputs AI 1 and AI 2
Analog inputs AI 3 and AI 4
Analog inputs AI 5 and AI 6
Operating Instructions, 05/2016, A5E34382853K