Siemens sinamics dcp Operating Instructions Manual page 67

Dc/dc power converter
Hide thumbs Also See for sinamics dcp:
Table of Contents

Advertisement

Modules for option G63
Image 6-17
Terminal/connector arrangement on the "Cabinet Board"
Image 6-18
Terminal arrangement on the "Terminal Module Cabinet (TMC)"
Terminal assignment for option G63
The technical data for terminals X177_1, X177_2 and X177_5 corresponds to the
specifications for terminal X177 on the Connector Board in the version without option G63,
see Table 6-2 Assignment, terminal -X177 (Page 54).
Table 6- 8
Assignment of the terminals on the Terminal Module Cabinet (TMC) (overview)
Terminal
Function
X177_1, X177_2
1st terminal block (X177_1)
1, 2
AI 3 +, AI 3 -
3, 4
AI 4 +, AI 4 -
5, 6
AI 5 +, AI 5 -
7, 8
AI 6 +, AI 6 -
9, 10
24 VDC
11, 12, 13, 14
DI 0, 1, 2, 3
15, 16, 17, 18
DI/DO 4, 5, 6, 7
SINAMICS DCP
Operating Instructions, 05/2016, A5E34382853K
Analog input 3
Analog input 4
Analog input 5
Analog input 6
24 V supply (output)
Digital input 0, 1, 2, 3
Digital input/output 4, 5,
6, 7
6.5 Additional system components
Description
See X177.1 and 2
See X177.3 and 4
See X177.5 and 6
See X177.7 and 8
24 VDC, short-circuit proof
Max. load 200 mA (terminals 9, 10, 57, 58, 59 and
60 combined),
internal supply to digital ground and analog ground
See X177.11, 12, 13, 14
See X177.15, 16, 17, 18
Electrical connection
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents