Siemens sinamics dcp Operating Instructions Manual page 154

Dc/dc power converter
Hide thumbs Also See for sinamics dcp:
Table of Contents

Advertisement

Operation
8.4 Communication according to PROFIdrive
Error
Meaning
value
0x73
Parameter %s [%s]: Write access
only in the commissioning state,
Safety (p0010 = 95).
0x74
Parameter %s [%s]: Write access
only in the commissioning state, tech.
application/units (p0010 = 5).
0x75
Parameter %s [%s]: Write access
only in the commissioning state
(p0010 not equal to 0).
0x76
Parameter %s [%s]: Write access
only in the commissioning state,
download (p0010 = 29).
0x77
Parameter %s [%s] must not be writ-
ten during download.
0x78
Parameter %s [%s]: Write access
only in the commissioning state, drive
configuration (device: p0009 = 3).
0x79
Parameter %s [%s]: Write access
only in the commissioning state,
define drive type (device: p0009 = 2).
0x7A
Parameter %s [%s]: Write access
only in the commissioning state,
database configuration (de-
vice: p0009 = 4).
0x7B
Parameter %s [%s]: Write access
only in the commissioning state,
device configuration (de-
vice: p0009 = 1).
0x7C
Parameter %s [%s]: Write access
only in the commissioning state,
device download (de-
vice: p0009 = 29).
0x7D
Parameter %s [%s]: Write access
only in the commissioning state,
device parameter reset (de-
vice: p0009 = 30).
0x7E
Parameter %s [%s]: Write access
only in the commissioning state,
device ready (device: p0009 = 0).
0x7F
Parameter %s [%s]: Write access
only in the commissioning state,
device (device: p0009 not 0).
0x81
Parameter %s [%s] must not be writ-
ten during download.
0x82
Transfer of the control authority
(master) is inhibited by BI: p0806.
0x83
Parameter %s [%s]: Requested BICO
interconnection not possible.
154
Remark
BICO output does not supply float values. The BICO input,
however, requires a float value.
Operating Instructions, 05/2016, A5E34382853K
Additional
info
SINAMICS DCP