Siemens sinamics dcp Operating Instructions Manual page 55

Dc/dc power converter
Hide thumbs Also See for sinamics dcp:
Table of Contents

Advertisement

25
AI 0 +
Analog input 0
AI 0 -
26
27
AI 1 +
Analog input 1
AI 1 -
28
29
AI 2 +
Analog input 2
AI 2 -
30
Reference voltage
31
P10
Reference voltage ±10 V
(output)
32
N10
33, 34
M
Ground, analog
Terminals not used
35, 36
M
Ground, digital
37
Not used
38
Not used
39
Not used
40
Not used
Terminals not used
41
Supply
42
Ground
43
Not used
44
Not used
45
Not used
46
Not used
47
Not used
48
Not used
Analog outputs (assignable outputs)
49
AO 0
Analog output 0
50
M
Ground, analog
51
AO 1
Analog output 1
52
M
Ground, analog
Connections for temperature sensors
53
Temp1
54
Temp2 (sense cable)
SINAMICS DCP
Operating Instructions, 05/2016, A5E34382853K
Parameterizable input type (signal type):
Differential input ±10 V; 150 kΩ
Current input 0 mA - 20 mA; 300 Ω or 4 mA - 20 mA; 300 Ω resolu-
tion approx. 0.66 mV (±14 bit)
Common-mode controllability: ±15 V
Input type (signal type):
- Differential input ±10 V; 150 kΩ
Resolution approx. 0.66 mV (±14 bits)
Common mode controllability ±15 V
Tolerance ±1% at 25° C Stability 0.1% per 10° K
10 mA short-circuit proof
+13.7 V to +15.2 V, 300 mA short-circuit proof
(electronically protected)
If overload occurs: Alarm A60018
±10 V, max. 2 mA short-circuit proof, resolution ±15 bits
Sensor according to P50490 (see SINAMICS DCP List Manual). The
cable to the temperature sensor must be shielded and connected to
Electrical connection
6.4 Terminals and connectors
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents