After this has been done, p0976 is automatically set to 0 and p0009 is set to 1.
Deleting all user data
In addition to the actual parameter data set which saves the parameter assignment of the
unit in a non-volatile memory (ROM) of the device and which can be deleted using p0976 = 1
(restore factory settings), the following data also belongs to the non-volatile user data:
● DCC charts
● The DCC block library
● Additional parameter data sets (see p0802, p0803, p0804)
Note
DCC is not supported in software version V1.1.
This data is also saved in the non-volatile memory (ROM). All user data is deleted from the
ROM as follows:
p0009 = 30
p0976 = 200
The operation may take several minutes. The unit automatically powers up during this time.
As a result, the unit in STARTER goes offline. Re-connect with the drive. After this has been
done, p0976 is automatically set to 0 and p0009 is set to 0.
Note
Data on the memory card is not deleted by setting p0976 = 200. In spite of this, when
deleting all user data, it is not permissible that a memory card is inserted. An inserted
memory card would mean that for an automatic ramp-up after p0976 = 200, as usual, the
data would be read from the memory card (see also Chapter Memory card functions
(Page 113)). The device would ramp-up with the parameter assignment from the memory
card.
Access level
The parameters are subdivided into access levels. The SINAMICS DCP List Manual
specifies the access level at which the parameter can be displayed and modified. The
required access levels 0 to 4 can be set in p0003.
Table 8- 1
0 User-defined
1 Standard
2 Extended
SINAMICS DCP
Operating Instructions, 05/2016, A5E34382853K
Parameter reset
Start to delete all user data
Access levels
Access level
Parameters from the user-defined list (p0013)
Parameters for the simplest possible operations
Parameters for handling the basic functions of the unit
Remark
Operation
8.1 Operation
109