Operation
8.6 Communication via PROFINET IO
Settings in STARTER
The following settings are required in STARTER for communication via PROFINET:
● Options → Set PG/PC interface...
Image 8-42
Assigning the IP address and name for the PROFINET interface of the drive unit
Use STARTER to assign an IP address and a name to the PROFINET interface (e.g.
CBE20).
Requirement:
● Connect a direct EtherNet cable from the PG/PC to the PROFINET interface of the
Control Unit (CUD).
● Switch on the Control Unit (CUD).
The accessible nodes must be sought in STARTER:
● Project → Accessible nodes
The found nodes are then displayed in the dialog screen.
196
Setting the PG/PC interface
Operating Instructions, 05/2016, A5E34382853K