Technical data
B.1
Ambient conditions
Environmental classes according to EN 60721-3
Table B- 1
Environmental classes
Usage
Environmental condition
Operation
Mechanical stability
Climatic influences
Biological influences
Chemical influences
Transporta-
Mechanical stability
tion
Climatic influences
Biological influences
Chemical influences
Storage
Mechanical stability
Climatic influences
Biological influences
Chemical influences
SINAMICS DCP
Operating Instructions, 05/2016, A5E34382853K
Environmental
Remark
class
See
Vibration test according to EN 61800-5-1 (Table 27)
•
Remark
–
Test: Fc test according to IEC 60068-2-6
–
Motion: Sinusoidal
–
10 to 57 Hz: Amplitude = 0.075 mm
–
57 to 150 Hz: Acceleration = 1 g
–
Duration of vibration: 10 cycles per axis
3K3
According to EN60721-3-3
•
Maximum surrounding air temperature: 0°C to +40°C (up
•
to + 55°C with Derating (Page 244))
No condensation, splash water or icing permitted.
•
3B1
-
3C1
-
2M1
Vibration test:
•
–
2 to 9 Hz: Amplitude = 3.5 mm
–
9 to 200 Hz: Acceleration = 10 m/s
2K3
According to EN60721-3-2
•
Surrounding air temperature:
•
–
-25° C to +70° C
(briefly to -40° C for max. 24 h)
2B1
-
2C1
-
1M2
1K4
According to EN60721-3-1
•
Surrounding air temperature:
•
–
-25° C to +55° C (temperature fluctuations <= 20 K / h)
Before commissioning, make sure that any condensation has
dried out.
1B1
-
1C1
-
B
2
285