Copying parameter data sets from non-volatile memory to the memory card
There are three ways of copying parameter data sets from non-volatile memory (ROM) to the
memory card:
● The system is switched off
– Insert a memory card into the CUD
– Switch on the system
– The system is put into operation by the software in the "ROM"
– Then the complete updated parameter data set with the index 0 is automatically
● The system is switched on
– Insert a memory card into the CUD
– Execute the command "RAM to ROM" (p0977 = 1). The updated parameter data set is
● The system is switched on
– By the user, utilizing the parameter data transfer from ROM to the memory card:
Note
While saving (BOP20 flashes, RDY LED flashes), the device must NOT be switched off.
Switching off the device while saving leads to the loss of the most recently performed and
not yet saved device parameterization.
Note
When options are being used and with certain device configurations, the saving operation
can take several minutes.
Note
When a memory card is inserted, the RAM to ROM command (p0977 = 1) will copy the
parameter data set with the index 0 from the ROM to the memory card. A parameter data set
that might have been previously saved on the memory card is overwritten.
SINAMICS DCP
Operating Instructions, 05/2016, A5E34382853K
copied from the "ROM" to the memory card without a prompt appearing.
copied automatically, first to the "ROM" and then as a data set to the memory card
with index 0. If the memory card already contains a parameter data set with the index
0, this will be overwritten without a prompt appearing.