5.14 SP5-XXX: MODE-3

5816*
Remote Service
I/F Setting
Turns the remote diagnostics off and on.
[0 to 2 / 2 / 1]
001
0: Remote diagnostics OFF.
1: Serial (CSS) remote diagnostics ON.
2: @Remote diagnostics. ON
CE Call
002
Lets the customer engineer start or end the remote machine check with CSS
or @Remote; to do this, push the center report key
Function Flag
Enables or disables the remote service function.
003
[0 to 1 / 0 / 1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
SSL Disable
Controls if RCG (Remote Communication Gate) confirmation is done by SSL
during an RCG send for the @Remote over a network interface.
007
[0 to 1 / 0 / 1]
0: Yes. SSL not used.
1: No. SSL used.
RCG Connect Timeout
008 Sets the length of time (seconds) for the time-out when the RCG (Remote
Communication Gate) connects during a call via the @Remote network.
[1 to 90 / 30 / 1 sec.]
RCG Write Timeout
009
Sets the length of time (seconds) for the time-out when sent data is written to
the RCG during a call over the @Remote network.
SM
5-95
SP5-xxx: Mode-3
D009/D011/D012/D013