SP5-xxx: Mode-3
3: Cannot detect dial tone automatically
4: Line is disconnected
5: Insufficient electrical power supply
6: Line classification not supported
7: Error because fax transmission in progress – ioctl() occurred.
8: Other error occurred
9: Line classification still in progress. Please wait.
Selection Dial/push
This SP displays the classification (tone or pulse) of the telephone line to the
access point for embedded RCG-M. The number displayed (0 or 1) is the
result of the execution of SP5816-151. However, this setting can also be
153
changed manually.
[0 to 1 / 0 / 1 /step]
0: Tone Dialing Phone
1: Pulse Dialing Phone
Outside Line Outgoing Number
The SP sets the number that switches to PSTN for the outside connection for
embedded RCG-M in a system that employs a PBX (internal line).
If the execution of SP5816-151 has succeeded and embedded RCG-M
has connected to the external line, this SP display is completely blank.
If embedded RCG-M has connected to an internal line, then the number of
154
the
connection to the external line is displayed.
If embedded RCG-M has connected to an external line, a comma is
displayed with
the number. The comma is inserted for a 2 sec. pause.
The number setting for the external line can be entered manually
(including commas).
Remove Service: PPP Certification Timeout (SSP)
155 Sets the length of the timeout for the embedded RCG-M connection to its
access point. The timeout is the time from when the modem sends the ATD to
when it receives the result code.