SP5-xxx: Mode-3
Default: 0
Allowed: Up to 16 numeral characters
Line Connecting
This SP sets the connection conditions for the customer. This setting dedicates
the line to embedded RCG-M only, or sets the line for sharing between
embedded RCG-M and a fax unit.
[0 or 1 / 0 / - ]
164
0: Line shared by embedded RCG-M/Fax
1: Line dedicated to embedded RCG-M only
If this setting is changed, the copier must be cycled off and on.
SP5816-187 determines whether the off-hook button can be used to
interrupt an embedded RCG-M transmission in progress to open the line
for fax transaction.
Modem serial No.
173
This SP displays the serial number registered for the embedded RCG-M.
Retransmission Limit
Normally, it is best to allow unlimited time for certification and ID2 update
requests, and for the notification that the certification has been completed.
However, embedded RCGM generates charges based on transmission time
174
for the customer, so a limit is placed upon the time allowed for these
transactions.
If these transactions cannot be completed within the allowed time, do this SP
to cancel the time restriction.
RCG - C M Debug Bit SW
186
FAX TX Priority
This SP determines whether pushing the off-hook button will interrupt an
187
embedded RCGM transmission in progress to open the line for fax transaction.
This SP can be used only if SP5816-164 is set to "0".
[0 or 1/ 0 / - ]
D009/D011/D012/D013
5-104