NCU Parameters
and Di closing
7.
Tone signals which frequency is lower than 1500Hz (e.g., 800Hz tone for AI short
protocol) refer to the setting at 6805B5h. Tones which frequency is higher than 1500Hz
refer to the setting at 6805B6h.
8.
68054A, 68054D, 68054E: The actual inter-digit pause (pulse dial mode) is the sum of
the period specified by the RAM addresses 68054A, 68054D, and 68054E.