Ricoh D009 Service Manual page 223

Hide thumbs Also See for D009:
Table of Contents

Advertisement

follow this procedure to calibrate the touch screen.
Do not attempt to use items [2] to [7] on the Self-Diagnostic Menu. These items are
for design use only.
1.
Press
,
2.
On the touch screen press "Touch Screen Adjust" (or press
3.
Use a pointed (not sharp!) tool to press the upper left mark
4.
Press the lower right mark
5.
Touch a few spots on the touch panel to confirm that the marker (+) appears exactly
where the screen is touched.
If the + mark does not appear where the screen is touched, press Cancel and repeat
from Step 2.
6.
When you are finished, press [#] OK on the screen (or press
7.
Touch [#] Exit on the screen to close the Self-Diagnostic menu and save the calibration
settings.
SM
, and then press
5 times to open the Self-Diagnostics menu.
after it appears.
3-93
Copy Adjustments
).
.
).
D009/D011/D012/D013