061 SDK2
071 SDK3
Authentication Error Code
5481
These SP codes determine how the authentication failures are displayed.
001 System Log Disp
002 Panel Disp
MF Key Card (Japan only)
Sets up operation of the machine with a keycard.
5490
[0 to 1 / 0 / 1]
0: Disabled. Cancels operation without a user code.
1: Enabled. Allows operation without a user code.
5501*
PM Alarm
PM Alarm Interval
001 Sets the PM alarm interval.
[0 to 9999 / 0 / 1 k copies/step]
0: No PM alarm
Original Count Alarm (DFU)
002
Selects whether the PM alarm for the number of scans is enabled or not.
If this is "1", the PM alarm function is enabled.
SM
Determines whether certification is required
before a user can use the SDK application.
[0 or 1 / 0 / -]
0: OFF [Default], 1: ON
Determines whether an error code appears in the
system log after a user authentication failure occurs.
[0 or 1 / 1 / 1]
0: OFF, 1: ON [Default]
Determines whether an error code appears on the
operation panel after a user authentication failure
occurs.
5-87