Bit Switches
Alarm when the handset is
off-hook at the end of
1
communication
0: Disabled
1: Enabled
2/3 Not used
Sidaa manual calibration
setting
4
0: Off
1: On
5-7 Not used

4.3.6 G3-2/3 SWITCHES

These switches require an optional G3 interface unit.
G3-3 switches are the same as for G3-2 switches.
G3-2 Switch 00 [SP No. 1-106-001]
No
FUNCTION
Monitor speaker during
communication (tx and rx)
Bit 1: 0, Bit 0: 0 = Disabled
0-1
Bit 1: 0, Bit 0: 1 = Up to Phase
B
Bit 1: 1, Bit 0: 0 = All the time
Bit 1: 1, Bit 0: 1 = Not used
Monitor speaker during
2
memory transmission
0: Disabled 1: Enabled
3-7 Not used
D346
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to "1".
Do not change the settings.
1: manually calibrates for communication with a
line, whose current change occurs such as an
optical fiber line.
Do not change the settings.
COMMENTS
(0, 0): The monitor speaker is disabled all through
the communication.
(0, 1): The monitor speaker is on up to phase B in
the T.30 protocol.
(1, 0): Used for testing. The monitor speaker is on
all through the communication. Make sure that you
reset these bits after testing.
1: The monitor speaker is enabled during memory
transmission.
Do not change the settings.