6.16 PAPER EXIT
6.16.1 OVERVIEW
1. Paper exit sensor
2. Paper overflow sensor
3. Junction gate jam sensor
4. Junction gate 2
This machine has two junction gates around the paper exit unit (junction gate 2 is located in
the duplex unit):
Junction gate 1 switches the paper feed direction to the standard output tray path or the
duplex unit path/1-bin tray path. This gate is controlled by the junction gate 1 solenoid.
When the junction gate 1 HP sensor detects that the gate is at home position, the
standard output tray path is opened.
Junction gate 2 switches the paper feed direction to the 1-bin tray path or duplex unit
path. This gate is controlled by the junction gate 2 solenoid in the 1-bin tray. If the 1-bin
tray is not installed, junction gate 2 does not move (the 1-bin tray path is always closed).
The paper exit motor drives the paper exit rollers and the junction transport roller.
SM
5. Junction Transport Roller
6. Junction gate 1
7. Fusing exit sensor
8. Paper exit rollers
6-73
Paper Exit
D009/D011/D012/D013