Memory Clear: Sp5-801 - Ricoh D009 Service Manual

Hide thumbs Also See for D009:
Table of Contents

Advertisement

1.
Execute SP5-802 to perform a free run of about 50 sheets.
2.
Open SP1-109-1, press
3.
Press Copy Window to return to the copy window.
4.
Place an OHP sheet (A4/8.5" x 11" LEF) on the by-pass feed tray.
5.
Press Start
twice. The OHP sheet stops in the fusing unit for about 10 seconds, then
it exits automatically.
6.
Check the nip bandwidth [A].
Check the nip bandwidth around the center of the OHP.
Nip band Specification: 7.0 ± 0.5 mm

5.29.4 MEMORY CLEAR: SP5-801

Executing Memory All Clear resets all the settings stored in the NVRAM to their default
settings except the following:
Electrical total counter value
SP5-811-1:
Machine serial number
SP5-907:
Plug & Play Brand Name and Production Name Setting
1.
Execute SP5-990 to print out all SMC Data Lists.
2.
Open SP mode 5-801.
3.
Press the number for the item that you want to initialize. The number you select
determines which application is initialized. For example, press 1 if you want to initialize
all modules or select the appropriate number from the table below.
5801-001 All Clear
002 Engine Clear
003 SCS
004 IMH Memory Clear
SM
, and then press Yes to confirm the selection.
Initializes items 2 to 15 below.
Initializes all registration settings for the engine
and copy process settings.
Initializes default system settings, SCS (System
Control Service) settings, operation display
coordinates, and ROM update information.
Initializes the image file system.
5-239
Using SP Modes
D009/D011/D012/D013