Main SP Tables-5

SP5-XXX (Mode)

[mm/inch Selection]
5024
Selects whether mm or inches are used in the display.
Note: After selecting the number, you must turn the main power switch off and on.
5-024-001 0:mm 1:inch
[Accounting counter]
Selects whether the accounting counter is displayed on the LCD or not.
5045
SP5-801-001/003 will not clear this SP. The value will be under an exclusive control
because the value varies in segments.
5-045-001 Counter Method
[Refill Toner Disp]
5051
Enables or disables the toner refill detection display.
5-051-001 -
[Display IP Address]
5055
Display or does not display the IP address on the operation panel.
5-055-001 -
[0 or 1 / 1 / 1/step]
C
0: mm (Europe/Asia)
1: inch (USA)
[0 or 1 / 0 / 1/step ]
C
0: Pattern 1
1: Pattern 2
[0 or 1 / 0 / 1/step]
C
0: On
1: Off
[0 or 1 / 0 / 1/step]
C
0: Off
1: On