0: 6 s 1: 12 s
7
Not used
G3 Switch 0B - Not used (do not change the settings).
G3 Switch 0C - Not used (do not change the settings)
G3 Switch 0D - Not used (do not change the settings).
G3 Switch 0E [SP No 1-105-015]
Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the
3-second CNG interval.
0-7
High order bit
Low order bit
G3 Switch 0F [SP No. 1-105-016]
No
FUNCTION
Alarm when an error occurred
in Phase C or later
0
0: Disabled
1: Enabled
SM
data after the local machine accepts set-up data
and sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
Do not change the settings.
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ FF (2250 ms)
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ 0F (3700 ms)
COMMENTS
If the customer wants to hear an alarm after each
error communication, change this bit to "1".
99