4.3.1 SYSTEM SWITCHES

System Switch 00 [SP No. 1-101-001]
No
FUNCTION
Dedicated transmission
0
parameter programming
0: Disabled, 1: Enabled
1
Not used
Technical data printout on the
Journal
0: OFF
1: ON
e.g. 0000 (1) // 32 (2) V34 (3) // 288 (4) // 264 (5) // L0100 (6) 03 (7) 04 (8)
(1): EQM value (Line quality data). A larger number means more errors.
(2): Symbol rate (V.34 only)
(3): Final modem type used
(4): Starting data rate (for example, 288 means 28.8 kbps)
(5): Final data rate
(6): Rx revel (refer to the note after this table for how to read the rx level)
2
(7): Total number of error lines that occurred during non-ECM reception.
(8): Total number of burst error lines that occurred during non-ECM reception.
EQM and rx level are fixed at "FFFF" in tx mode.
The seventh and eighth numbers are fixed at "00" for transmission records
and ECM reception records.
Rx level calculation
Example: 0000 // 32 V34 // 288/264 // L 01 00 03 04
The four-digit hexadecimal value (N) after "L" indicates the rx level.
The high byte is given first, followed by the low byte. Divide the decimal value of N
by -16 to get the rx level.
In the above example, the decimal value of N (= 0100 [H]) is 256.
SM
COMMENTS
Set this bit to 1 before changing any dedicated
transmission parameters.
Reset this bit to 0 after programming dedicated
transmission parameters.
Do not change
1: Instead of the personal name, the following data
are listed on the Journal for each G3
communication.
57