VISTA-128B Installation and Setup Guide
Installing the FSA Modules
The module will not operate until the device address you have set the DIP switches for is enabled
in the control's Device Programming in the #93 Menu Mode .
To install the FSA module, perform the following steps:
Step
1
2
3
Wiring the 4300 Transformer
Powerline Carrier devices (such as X-10, ACT, Leviton) are either plugged into standard AC
outlets or wired into the AC electrical system by a licensed electrician, depending on the type
of device used. They respond to "on" and "off" commands sent from the panel, through the
4300 transformer, to the receiving devices.
Note each device's House and Unit Code setup, as these codes will be used to program the
devices in the Output Programming in the #93 Menu Mode .
9-4
Action
Set the FSA module's DIP switches for a device address between 08-23. See the
module's instructions for the DIP switch table.
Make sure the address is not being used by another device (keypads, RF
receivers, etc.).
Mount the FSA module horizontally to a duplex box (quad box for FSA-24).
Connect the module to the control's keypad terminals (6, 7, 8, and 9).
Optional
Keyswitch
Connection
Terminal
Block
SIDE
VIEW
All Switches shown
in Up position.
(ECP Address 23)
Figure 9-3: Wiring the FSA Module
Dip Switch
0 0 0 0 0
Connect to
Keypad
Terminals
ECP Bus