Additional Commands
Action Code
75 Run Macro
76 Run Script
77 Access Point Group Enable
78 Access Point Group Disable
3) Enter the desired activation time, which refers to when the action is to take place
relative to the time window. Select from:
Activation Time
Automatic Refresh Feature
The system automatically updates the status of all Time-Driven Events upon any of the
following occurrences:
Changing of the time or date via #63 mode
Exiting #80 Scheduling Menu mode
Exiting Program mode
After a disconnect from the downloader
On a power-up
At Daylight Saving Time adjustment.
Time-Driven Event Programming
The following schedules can be used to activate outputs, bypass zones, arm/disarm the
system, etc. based on a time schedule. Up to 20 events can be programmed for the system.
Time windows must first be defined in order to be used to trigger events.
If using time-driven events to control relays, the following menu items must first
be programmed using Output Programming in the #93 Menu Mode:
Enter Relay No.
Output Group
Restriction
Output Type
ECP Address
Relay No.
Description
1
Beginning of time window
2
End of time window
3
During time window active period only (On at beginning of
window, off at end). This can be used in conjunction with the
arm, disarm or bypass commands to control a part of the
system during the window.
For example, if bypass is selected to activate during the
window, the zones in the zone list will be bypassed at the
beginning of the window and unbypassed at the end of the
window.
4
Beginning and end of time window (e.g., -a Coffee break
buzzer). In this example, if relay pulse is selected, the relay will
pulse for 2 seconds at the beginning of the window, signaling
the beginning of the coffee break. At the end of the window it
will pulse again, signaling the end of coffee break.
(reference identification number)
(if applicable)
(4101SN, 4204, X-10, or FSA)
if 4204 relays
Section 24 – Scheduling Options
Action Specifier
Macro #
Script #
Group #
Group #
24-13