ADEMCO Contact ID Reporting takes the following format:
CCCC QEEE GG ZZZ
Code
Definition
110
Fire Alarm
121
Duress
122
Silent Panic
123
Audible Panic
124
Duress Access Grant
125
Duress Egress Grant
131
Perimeter Burglary
132
Interior Burglary
133
24-Hour Burglary
134
Entry/Exit Burglary
135
Day/Night Burglary
140
ACS Zone Alarm
142
Polling Loop Short Alarm
150
24-Hour Auxiliary
301
AC Loss
302
Low System Battery
305
System Reset
306
Program Tamper
308
System Shutdown
309
Battery Test Fail
310
Ground Fault
313
System Engineer Reset
320
ACS Relay Supervision
332
Poll Loop Short-Trouble
333
Expansion Module Failure
338
ACS Module Low Battery
339
ACS Module Reset
342
ACS Module AC Loss
343
ACS Module Self-Test Fail
354
ACS RS232 Fail
373
Fire Loop Trouble
374
Exit Error by Zone
380
Trouble (global)
381
Loss of Supervision (RF)
382
Loss of RPM Supervision
383
RPM Sensor Tamper
384
RF Transmitter Low Battery
389
Detector Self-Test Failed
401
O/C by User
403
Power-Up Armed/Auto-Arm
406
Cancel by User
407
Remote Arm/Disarm (Download)
408
Quick Arm
CCCC =
Customer (subscriber) ID
Q =
Event qualifier, where:
E = new event, and R = restore
EEE =
Event code (3 hexadecimal digits)
GG =
Partition number (system messages show "00")
ZZZ =
Zone number for an alarm, or user number for Open/Close
reports. System status messages (AC Loss, Walk-Test, etc.)
contain zeroes.

TABLE OF CONTACT ID EVENT CODES

Section 25 – System Communication
Code
Definition
409
Keyswitch O/C
411
Callback Requested
421
Access Denied
422
Access Granted
423
Door Force Open
424
Egress Denied
425
Egress Granted
426
Door Prop Open
427
Access Point DSM Trouble
428
Access Point RTE Trouble
429
ACS Program Entry
430
ACS Program Exit
431
ACS Threat Change
432
Access Point Relay/Trigger Fail
433
Access Point RTE Shunt
434
Access Point DSM Shunt/Unshunt
441
Armed STAY
451
Early Open/Close
452
Late Open/Close
453
Fail to Open
454
Fail to Close
455
Auto-arm Fail
457
Exit Error by User
459
Recent Close
501
ACS Reader Disable
520
ACS Relay Disable
570
Bypass
576
ACS Zone Shunt
577
ACS Point Bypass
602
Communicator Test
606
Listen-In to Follow
607
Burglary Walk-Test
621
Event Log Reset
622
Event Log 50% Full
623
Event Log 90% Full
624
Event Log Overflow
625
Time/Date Reset
631
Exception Schedule Change
632
Access Schedule Change