Audio Alarm Verification Module Program Options; Figure 11-2: Aav Connections Using A 4204 Relay Module; Figure 11-3: Aav And 4286 Vip Module Connections Using The J7 Trigger - ADEMCO VISTA-128B Installation And Setup Gude

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

Figure 11-3: AAV and 4286 VIP Module Connections Using the J7 Trigger

Audio Alarm Verification Module Program Options

If you need information about actual programming procedures, see The Mechanics of
Programming section.
Program the following data fields:
*45
1*46
1*60
Set CANCEL REPORT to a non-zero digit in System Group #1 in Report Code Programming
in the #93 Menu Mode.
EAGLE
SUPPLIED
CABLE
CONTROL/
DIALER HEADER
DIP Switch
• •
EAGLE
1250

Figure 11-2: AAV Connections Using a 4204 Relay Module

(–) EDGE TRIGGER (YELLOW)
EAGLE
SUPPLIED
CABLE
CONTROL/
DIALER HEADER
NOTE:
REFER TO AAV MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
DIP Switch
• •
• •
EAGLE
1250
PRIMARY DIALER FORMAT: Set for 1 (Contact ID).
AUXILIARY OUTPUT ENABLE: Set for 3 (unless using 4204 Relay Module).
ZONE 5/AUDIO ALARM VERIFICATION: Set for 1.
Section 11 – Audio Alarm Verification (AAV) Unit
CONTROL
ZONE 5
6
7
16 17
(–)
(+)
4204
RED
13
V+
14
RELAY 1
BROWN
15
SHOWN
GND
OFF
16
NO NC C
BROWN (–)
RED (+)
NOTE:
REFER TO AAV MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
TIP
RING
PIN 3
DIODE FROM
EOLR PACKAGE
CONTROL
ZONE 5
16 17
6
7
(+)
(–)
(–)
(+)
SYSTEM POWER (RED)
SYSTEM GROUND (BROWN)
BROWN (–)
RED (+)
TIP
RING
J7
EARTH
26
27
28 29 30
GROUND
RED (R)
GREEN (T)
GREY (R)
RJ31X
BROWN (T)
TO PREMISES
HANDSET
INCOMING
PHONE LINE
J7
EARTH
26
27
28 29 30
GROUND
RED (R)
GREEN (T)
RJ31X
INCOMING
PHONE
LINE
TO PREMISES
HANDSET
4 3 2 1
4286
11-3

Advertisement

Table of Contents
loading