7920SE WIRING
CONTROL
NOTES:
FOR UL LISTED COMMERCIAL BURGLARY
INSTALLATIONS:
1. MOUNT THE 7920SE WITH 3 FEET OF THE
C-COM. RUN WIRING FROM C-COM TO
7920SE IN CONDUIT.
2. CONNECT RADIO OK OUTPUT TO C-COM
EOLR SUPERVISED ZONE (ZONE 2-7 ONLY).
USE 2K EOLR.
3. SEE UL INSTALLATION REQUIREMENTS ON A
LATER PAGE TO DETERMINE WHEN 659EN
USAGE IS REQUIRED.
4. CONNECT TO C-COM EOLR SUPERVISED
ZONE (ZONE 2-8 ONLY) WHEN DESIRED TO
HAVE PANEL LOCALLY ANNUNCIATE PHONE
LINE FAULTS.
NOTE 1: CONNECT TO CONTROL PANEL'S HARDWIRE ZONES (2-8) USE 2K EOLR
NOTE 2: MOUNT THE 7720 WITHIN 3 FEET OF THE C-COM. RUN WIRING FROM C-COM TO 7720 IN CONDUIT.
Programming for Auxiliary Alarm Signaling Equipment
Program the following data fields:
*15
KEYSWITCH ENABLE: Make sure this field is set to 0. The keyswitch and the
auxiliary alarm signaling equipment cannot be used together.
1*46 AUXILIARY OUTPUT ENABLE: Set to "0" (factory default)

Event Log Printer

The VISTA-128B's event log can be printed on a local serial printer.
Connect a UL EDP Listed serial printer to the J8 connector using an ADEMCO 4100SM
Interface Module. Refer to Event Log Options section for wiring connections, printer
configuration, and a description of the keypad commands for event log printing.
12-6
PANEL
J7
28 29 30
TO C-COM AUX PWR
(35mA DRAW)

Figure 12-6: Connections to 7920SELong Range Radios

RADIO FAULT
(PROGRAM FOR
SHORT ON FAULT)
SEE NOTE 1
GRAY
4142TR
CABLE
GRAY GROUND
RED FIRE ALARM
BLACK SILENT PANIC / DURESS ALARM
BROWN BURG / AUDIBLE PANIC ALARM

Figure 12-7: Connections to 7720ULF Long Range Radio

CONNECT TO
C-COM EARTH
GROUND SCREW
(TB30)
4142TR CABLE
GND (GRAY)
FIRE
SILENT PANIC/DURESS
BURG/AUDIBLE PANIC
4.7K
(NOT SUPPLIED)
SEE NOTE 2
7 BLACK
659EN LINE FAULT MONITOR
}
6 RED
+12V GND
ORANGE
FAULT
YELLOW
GREEN
1 2 3 4 5 6 7 8
PHONE LINE MONITOR
SEE NOTE 4
(+12V ON FAULT)
OPTIONAL
7720 ULF RADIO
J5
FAULT
9
8
- CUT RESISTOR JUMPERS Z1-Z3.
FAULT
7
- DO NOT USE 2k EOL RESISTOR.
6
- PROGRAM 7720 ULF FOR SLAVE
5
4
3
2
1
1
2
3 4 5
6
7920SE RADIO
SEE 7920SE INST. INSTR. FOR
INSTRUCTIONS ON POWERING UNIT
EARTH GROUND
CABINET GROUND
TB1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
TB2
(RED)
OPTIONAL
(BLACK) OPTIONAL
(BROWN) REQUIRED
RADIO OK OUTPUT
(LOW ON FAULT)
PHONE LINE MONITOR
(OPENS ON FAULT)
REQUIRED
INCOMING PHONE LINE
SEE 7720 ULF INSTRUCTIONS FOR
MORE DETAILED INSTALLATION
INFORMATION
OPERATION. PROGRAM ZONES 1-3
AS ALARM ZONES
7
8
9 10 11 12 13 14 15 16
7720ULF_1