VISTA-128B Installation and Setup Guide
Additional zone faults will be displayed one at a time. To display a new partition's status,
press
The Armed LED on a master keypad will be lit only if all partitions have been armed
successfully. The Ready LED will be lit only if all partitions are "ready to arm." Neither
LED will be lit if only some partitions are armed and/or only some partitions are ready.
The sounder on a master keypad will reflect the sound of the most critical condition on all of
the partitions. The priority of the sounds is as follows:
1. Pulsing fire alarm sounds
2. Steady burglar alarm sounds
3. Trouble sounds (rapid beeping)
Silence the sounder by pressing any key on the master keypad or a keypad on the partition
where the condition exists.
A master keypad uses the same panics as Partition 1. Master keypad panics are sent to Partition
1, and will activate on Partition 1. Therefore, panics must be programmed for Partition 1.
2-6
+ [Partition No.].