"CHECK" accompanied by a numeric display of "8XX," where XX = 00-31, indicates a
trouble on a peripheral device (connected to the panel's keypad terminals) of the
corresponding device address (00-31).
"CHECK" accompanied by a numeric display of "9XX," where XX = 00-99, indicates that a
system trouble exists (dialers, bell outputs, ground fault, etc.). See the Zone Index/Zone
Type Defaults section.
If the problem has been corrected, key an OFF sequence (Security Code plus OFF) twice to clear
the display.
Other System Messages
"COMM. FAILURE" at the keypad indicates that a failure occurred in the telephone
communication portion of your system.
"LO BAT" and a zone descriptor, accompanied by a once-per-minute beep at the keypad,
indicates that a low battery condition exists in the wireless transmitter displayed.
Pressing any key will silence the audible warning sound.
"SYSTEM LO BAT" at the keypad indicates that a low battery condition exists with the
system's backup battery.
"RCVR SET UP ERROR" at the keypad indicates that the system has more wireless
zones programmed than the wireless receiver can support. If this is not corrected, none of
the zones in the system will be protected. If additional wireless zones are desired, use an
appropriate receiver.
"MODEM COMM" at the keypad indicates that the control is on-line with a remote
computer.
System Off-Normal Report
If programmed, a unique Off-Normal report will be generated instead of the periodic test
report if any of the following conditions are present at the time of the report:
This report will be sent as follows:
Contact ID: Code 608
High Speed: Channel 3 of system report used (channel 9=6)
Low Speed: Digits programmed in System Group #4 report codes (Report Code Programming
in the #93 Menu Mode).
Power Failure
If the POWER indicator is off, and the message "AC LOSS" is displayed, the keypad is
operating on battery power only. Check to see that the circuit breaker for the branch circuit
that your system's transformer is wired to has not been accidentally turned off. Instruct the
user to call a service representative immediately if AC power cannot be restored.
30-4
Fire trouble on any zone (zone response types 9)
Unrestored fire alarm on any zone
Fault on LORRA "XMIT OK" signal (if enabled)
LORRA trigger bypassed
AC failure
Low system battery
Keypad supervision fault