Zone Index/Zone Type Defaults; Zone Index - ADEMCO VISTA-128B Installation And Setup Gude

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section

Zone Index

Zone Type Defaults
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Zone Index
The VISTA-128B has 128 protection zones, as well as supervisory zones for relays, ECP
devices (devices which communicate through the keypad terminals), and system troubles.
These zones are designated as follows:
ZONE # RANGE
001 - 128
601 - 632
800 - 830
970, 988,-990, & 997
995 - 999
Response types for zones are enabled in Zone Programming in the #93 Menu Mode.
Supervisory zones should be given a response type of 05 (Trouble by Day, Alarm by Night).

Zone Index/Zone Type Defaults

ZONE FUNCTION
Protection zones
Relay Supervisory Zones
ECP Device Supervisory Zones
(includes keypads, wireless
receivers, VIP Module, relay
modules, etc.)
System Supervisory Zones
Keypad Panics
S E C T I O N
ACTUAL ZONE
As indicated
6 + 2-digit Relay Number; e.g., Relay
Number 03, if supervised, is zone
603.
8 + 2-digit Device Address; e.g.,
Device Address 01, if supervised, is
zone 801. The 4285/4286 VIP
Module is zone 804 (since its Device
Address must be set to 4).
970: Bell Supervision
988: 2nd Wireless Receiver - not
receiving signals
990: 1st Wireless Receiver - not
receiving signals
997: Polling Loop (short circuit)
995: 1 + ∗ panic (A key)
996: 3 + # panic (C key)
999: ∗ + # panic (B key)
2 1