Figure 6-4. Wiring Latching Glassbreak Detectors To Zone 8 - ADEMCO VISTA-128B Installation And Setup Gude

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

The alarm current provided by zone 8 will support only one glassbreak detector in the alarmed
state.
Do not use other N.O. or N.C. contacts when using glassbreak detectors on zone 8. Other
contacts may prevent proper glassbreak detector operation.
Wiring 2-wire Glassbreak Detectors
To wire 2-wire glassbreak detectors, perform the following steps:
Step
Action
Select from the list compatible 2-wire latching glassbreak detectors.
2
Connect detectors across zone 8 (terminals 21 and 22). See Figure 6-4.
3
Connect the EOL resistor across the loop wires at the last detector.

Figure 6-4. Wiring Latching Glassbreak Detectors to Zone 8

GLASSBREAK
DETECTOR
2000
OHMS
EOLR
LATCHING TYPE GLASS
BREAK DETECTOR LOOP
Section 6 – Basic Hardwired Zones
ZONE 8
(+)
21
(-)
22
6-5