VISTA-128B CONTROL
Physical:
Electrical:
Voltage Input:
Alarm Sounder Output:
Auxiliary Power Output:
Backup Battery:
Standby Time:
Circuit Protectors:
Digital Communicator
Formats Supported:
Line Seize:
Ringer Equivalence:
FCC Registration No.:
6139 Remote Keypads
Physical:
Width:
Height:
Depth:
Electrical:
Voltage Input:
Current Drain:
Interface Wiring:
RED:
BLUE:
GREEN:
YELLOW:
BLACK:
14-1/2"W X 18"H X 4.3"D
From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada) or 4300
transformer (for X-10 installations) rated 16.5VAC, 40 VA.
10VDC-13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux.
current draw (UL985 installations).
9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories connected to the
output must be UL Listed, and rated to operate in the above voltage range.
12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH)
recommended.
4 hours min. with 750 mA aux. load using 7 AH battery.
PTC circuit breakers are used on battery input to protect against reverse battery
connections and on alarm sounder output to protect against wiring faults (shorts).
A solid state circuit breaker is used on auxiliary power output to protect against wiring
faults (shorts).
ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO
Contact ID, Sescoa and Radionics Low Speed
Double Pole
0.7B
AC398U-68192-AL-E
6.25 inches
4.75 inches
1.25 inches
12VDC
100 mA
12VDC input (+) auxiliary power
Not Used
Data to control panel
Data from control panel
Ground and (-) connection from supplemental power supply.