Using The Vista-128B For Stand-Alone Access Control - ADEMCO VISTA-128B Installation And Setup Gude

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

VISTA-128B Installation and Setup Guide

Using the VISTA-128B for Stand-alone Access Control

The VISTA-128B can be used for access control without interfacing to PassPoint ACS. A user
can trigger an access point (i.e., door strike) for 2 seconds by entering [User Code] + [0].
Programming the Control for Stand-alone Access Control
Step
1
2
3
4
5
See Output Programming in #93 Menu Mode Programming in the Programming Guide for a
detailed explanation.
14-8
Action
Enter Output Programming in the #93 Menu Mode.
Program the output type as 1, 2, or 3.
For type 1, program the ECP address and relay #.
For type 2, program the house and unit codes
Program the relay number in field 1∗76 (partition-specific).