UL Installation Requirements

The following requirements apply to both UL residential and UL commercial burglary
installations:
All partitions must be owned and managed by the same person(s).
All partitions must be part of one building at one street address.
The audible alarm device(s) must be placed where it/they can be heard by all partitions.
The control cabinet must be protected from unauthorized access. This can be done by
installing a tamper switch on the cabinet door (not supplied with VISTA-128B) or by
installing a UL Listed passive infrared detector positioned to detect cabinet access. Wire
the selected device to any EOLR-supervised zone (Zone 1-8). Program this zone for day
trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour
alarm response must be used for multiple partitioned systems.
Remote downloading and auto-disarming are not UL Listed features.
UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault
Use the VISTA-128B.
All zones must be configured for EOLR supervision (*41=0). Wireless sensors may not be
used. If 4190WH RPMs are used, set field *24 to "0" to enable tamper detection.
Attach a door tamper switch (supplied) to the VISTA-128B cabinet backbox. For safe and
vault installations, a shock sensor (not supplied) must also be attached to the backbox.
(Also see Mounting the Cabinet in the Installing the Control section)
Wire an ADEMCO AB12 Grade A Bell/Box to the bell output. Bell wires must be run in
conduit. Program the bell output for 16 or longer timeout and for confirmation of arming
ding. (Also see the External Sounders section)
Wire the VISTA-128B tamper switch and AB12 Bell/Box tamper switches to any EOLR
supervised zone (zones 1-8). Program this zone for day trouble/night alarm (type 05) or
24-hour audible alarm (type 07) response. The 24-hour alarm response must be used for
multiple partitioned systems.
Entry delays must not exceed 45 seconds, and exit delays must not exceed 60 seconds.

UL365 Police Station Connected Burglar Alarm

Follow the instructions for UL609 local installations given above.
For Grade A Service:
You may use the VISTA-128B dialer alone, or the 7720 Long Range Radio alone.
When using the dialer, program it to send Burglary Alarm, Low Battery and
Communicator Test reports. Field *27 must be set to "024" (or less) so that test reports
are sent at least once every 24 hours.
If using the 7720, connect it to the VISTA-128B burglary/audible panic alarm trigger.