Time-Driven Events Worksheet
Fill out the worksheet using the steps outlined below.
Sched
Time
Num.
Window
1
2
3...20
1) First enter the schedule number (01-20) and time window number (01-20), and
note the day of the week the action is desired.
2) Enter the code for the desired action and action specifier. The action codes are the
events that are to take place when the scheduled time is reached. Each action also
requires an action specifier, which defines what the action will affect (relay, relay group,
partition, zone list, user group). The action specifier varies, depending on the type of
action selected.
The following is a list of the "Action Codes" (desired actions) used when programming
time-driven events. Note that these codes are independent of the relay codes programmed
during the Output Programming in the #93 Menu Mode.
Relay commands
Action Code
01 Relay On
02 Relay Off
03 Relay Close for 2 seconds
04 Relay Close XX minutes (set in field 1*74)
05 Relay Close YY seconds (set in field 1*75)
06 Relay Group On
07 Relay Group Off
08 Relay Group Close for 2 seconds
09 Relay Group Close XX minutes (set in field 1*74) Relay Group #
10 Relay Group Close YY seconds (set in field 1*75)
Arm/Disarm Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for automatic
arming and disarming functions.
"During" can be used to arm and disarm the control for a specific time only. For example,
if "during" is selected with Arm-STAY, the system automatically Arms-STAY at the
beginning of the window and automatically disarms at the end of the window.
Action Code
20 Arm-STAY
21 Arm AWAY
22 Disarm
23 Force Arm STAY (Auto-bypass faulted zns)
24 Force Arm AWAY (Auto-bypass faulted zns)
The auto-arm warning (field 2*06) applies when using time-driven events to auto-arm.
Temporary schedules will not override an auto-arming or auto-disarming programmed in time-
driven events.
The auto-arming window cannot be extended using the Installer Code + #82 Mode.
Days
M T W T F S S H
Section 24 – Scheduling Options
Action
Action
Desired
Specifier
Action Specifier
Relay #
Relay #
Relay #
Relay #
Relay #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Action Specifier
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Activation
Time
24-11