Remote Keypad Sounder

An optional Amseco PAL 328N Piezo Sounder can be used to duplicate the sounds produced
by the keypad's built-in sounder. The panel will remote all sounds (e g.,. alarm, trouble,
chime, entry/exit, etc.) produced by the keypad's built-in sounder except for the short beeps
associated with keypad key depression. One application of this feature might be to produce
chime sounds at a distant location from the panel's keypads.
Remote Keypad Sounder Setup
To setup for a remote keypad sounder, perform the following steps:
Step
1
2
IF USED:
1. OUT 1 IS NO LONGER
USABLE FOR OPEN/CLOSE
OR GROUND START (SEE
FIELD 1*46).
2. OUT 2, 3, 4 CAN STILL BE
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
TO AUX POWER+
(10mA CURRENT DRAW)

Remote Keyswitch

An optional UL-Listed remote keyswitch, such as the ADEMCO 4146, can be used for remote
arming/disarming of the burglary portion of the system and for remotely silencing alarms.
The keyswitch can operate in only one particular partition.
Remote Keyswitch Setup
To setup for a remote keyswitch, perform the following steps:
Step
1
2
Action
Connect the piezo sounder to the panel's positive auxiliary power output and to
Output 1 on the J7 connector as shown in Figure 12-3.
Program the following data field:
1*46 AUXILIARY OUTPUT ENABLE: Set to "1"
RED
TERMIANL 6

Figure 12-3: Remote Keypad Sounder Wiring

Action
Connect the keyswitch as shown in figure 12-4. The tamper switch need not be
used for fire or UL household burglary installations.
For UL commercial burglary installations, the tamper switch must be wired to
zone 8, and zone 8 must be programmed for day trouble/night alarm (zone type 5).
When the keyswitch is removed from the wall, the tamper switch will open,
causing an alarm or trouble on zone 8, and causing the control to disable
keyswitch operation until the associated partition is disarmed from a keypad.
Program the following data fields:
*15
KEYSWITCH ENABLE: Assign the keyswitch to a partition (1-8).
*40
OPEN/CLOSE REPORT ENABLE: Enter 1 to enable.
1*46 AUXILIARY OUTPUT ENABLE: Set to "0" (factory default)
*93
ZONE PROGRAMMING: Assigned Zone 7 a non-zero response type.
4142TR
CABLE
BLACK
_
AMSECO PAL-328N
PIEZO SOUNDER
+
Section 12 – J7 Trigger Outputs
J7 CONNECTOR
GRAY (GROUND)
YELLOW (OUT 1)
WHITE (GROUND)
RED (OUT 2)
GREEN (GROUND)
BROWN (OUT 3)
BLUE (GROUND)
BLACK (OUT 4)