Figure 15-2: Wiring Nonpolarized Burglary Indicating Devices - ADEMCO VISTA-128B Installation And Setup Gude

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

VISTA-128B Installation and Setup Guide
UL1023 Household Burglary Installations
For household burglary installations the total current drawn from the alarm output must not
exceed 1.7A. A battery must be installed since the combined auxiliary power, polling loop,
and alarm output, in excess of 750mA must be supplied by the battery.
Wire nonpolarized burglary indicating devices to the alarm output using a polarizing diode
as shown in Figure 15-2.
PANEL BELL
+
-
PANEL BELL

Figure 15-2: Wiring Nonpolarized Burglary Indicating Devices

Non-UL Installations
For non-UL installations, the total current drawn from this output can be up to 1.7 amps. A
battery must be installed since current in excess of 750mA is supplied by the battery. Up to
two 719 sirens can be used wired in parallel.
Programming the Alarm Output
Program the following data fields:
*13
*16
*21
*23
1*47
15-4
POLARIZING DIODES
(MUST MOUNT AT INDICATING DEVICE)
BELL
NON- POLARIZED BURGLARY
INDICATING DEVICES
Select Timeout for Bell
Confirmation of Arming Ding for Bell
PREVENT FIRE TIMEOUT (1=no timeout; 0=fire timeout
MULTIPLE ALARMS (partition-specific)
Enable Chime for Bell
HORN
BELL
POLARIZED FIRE
INDICATING DEVICE
}
TO OTHER
DEVICES