Programming Partition-Specific Data Fields - ADEMCO VISTA-128B Installation And Setup Gude

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

To program system-wide data fields, do the following:
Step
1
2
3
4
5
If the number of digits that you enter in a data field is less than the maximum permitted
(for example, a phone number), the keypad displays the last entry and waits. To proceed,
enter [ ] + the next data field you wish to program (e.g., press ∗08).
Partition-Specific Programming Fields are skipped unless entered specifically.

Programming Partition-Specific Data Fields

To program partition-specific data fields once in Program Mode, do the following:
Step
1
2
3
4
Action
Enter Program Mode: [Installer Code] + 8 0 0 0.
After entry into the Program Mode, the following will be displayed:
Program Mode
*Fill # View -00
If the control has not been programmed before, enter *97 to load factory
defaults.
Press [ ] and enter the first field number to be programmed (for example,
∗00, Installer's Code). Make the desired entry. When the field is complete, the
keypad will beep three times and will advance to the next field. If you do not
desire to change the next field, press [ ] and enter the next field number to be
programmed.
First Page of fields
(*00-*90)
To change to the next page of fields, press *94. To return to the previous page of
fields, press *99.
Press *99 or *98 to exit Program Mode
Action
Enter Program Mode: [Installer Code] + 8 0 0 0.
After entry into the Program Mode, the following will be displayed:
Program Mode
*Fill # View -00
Press *91, which will prompt you for the partition number desired.
Enter a partition-specific field number (e.g., ∗09) to begin programming. When
the first field's entry is completed, the next partition-specific field will
automatically be displayed. When all partition-specific fields are programmed,
the system returns to the global programming fields (page 1 fields). To return to
the global program fields before finishing all fields, enter any global field number.
Repeat this procedure for each partition in the installation.
Section 19 - The Mechanics of Programming
19-3

Advertisement

Table of Contents
loading