Using an RF Transmitter Zone
A button type RF button-type transmitter (5804) can be used to provide access or egress for
up to 4 doors. One button will control one door. Also, a button can be used to provide access
or egress due to a panic or duress condition.
An RF transmitter (5816) can be used with a remote switch to provide exit in case of a fire
alarm using a PassPoint event action.
Programming the RF Transmitter
Step
Action
1
Enter Zone Programming in the #93 Menu Mode.
2
Program the zone with a response type 27 (Access Point).
3
Enter the access point number (00-31) of the door.
4
Indicate whether RF device is for entry or exit.
5
Enter the partition number
6
Enter the input type: button RF (05).
7
Enter the loop number.
8
Enroll the serial number
See Zone Programming in #93 Menu Mode Programming in the Programming Guide for a
detailed explanation.
RF buttons and pendants must be assigned to a user number in order to function. See the
User Access Codes section for the procedure.
An RF transmitter will not provide access or grant if the system is in any test mode.
Using Wireless Keypads
Wireless keypads (5827 & 5827BD) can provide another way of entering or exiting the
premises. They function the same as alpha keypads, except when the code + # 73 is entered.
This entry will allow momentary access to ALL access points in the partition to which the
keypad is assigned
Programming the Wireless Keypad
Enter the partition the keypad is assigned to in field 1*48.
Control of Lighting and Appliances
Lighting and appliances can be controlled when an access or exit event occurs. Lights or
appliances can be automatically turned on or off when a valid entry or egress request is
presented at an access point. To control these devices, the VISTA-128B relays or the ACS
relays or triggers are used with keypads and/or RF transmitters whose response type is
Access Point (27).
Programming the Control of Lighting and Appliances
Step
Action
1
Enter Output Programming in the #93 Menu Mode.
2
Program all the information for the relay.
3
Select the output type: ECP (1) (4204/4204CF) or (2) (X-10).
See Output Programming in #93 Menu Mode Programming in the Programming Guide for a
detailed explanation.
Section 14 – Access Control