Event Logging Procedures

In order for proper time and date stamping to occur, the system's real-time clock must be set.
Refer to the Setting the Real Time Clock section.
If you have selected the printer to be "on-line" (field 1*72), events will print automatically, as
they occur. To display or print on demand, the following commands apply:
Display/Printing: After entering either the Display or Print Mode, the following will be
displayed:
ENTER 0 = RECENT
1 = COMPLETE
SCAN LOG BY PART
0=NO 1-8=PART #
Use the [3] & [1] keys to scroll to the next and previous screens, respectively:
ALARM EVENT LOG
TYPE
CHECK EVENT LOG
TYPE
BYPASS EVENT LOG
TYPE
OP/CL EVENT LOG
TYPE
SYSTEM EVENT LOG
TYPE
Commands
Display Mode:
Print Mode:
Clear Event Log:
To EXIT Event Log:
The event log holds up to 512 events, and can display or print all
events in a category (complete), or only those events in a category
occurring since the last "Clear Event Log" command (recent). Note
that once the event log is full, the oldest event will be erased upon
the logging of any new event. Press the desired Display Mode key,
0 or 1.
The system allows viewing of any partition's event log. Enter the
partition number for the partition whose events are to be displayed.
Entering 0 (NO) will display all events that occurred in the system,
regardless of partition. Events are displayed in chronological
order, from most recent to oldest.
For display and printing purposes, events are stored on a partition-
by-partition basis (except system events), and are grouped into five
categories, as follows.
Displays time/date for zones that have either caused an alarm or
have been restored in selected partition.
CCC UUU
Displays time/date for zones that have caused a trouble or
supervisory condition in selected partition.
CCC UUU
Displays time/date for zones that have been bypassed in selected
partition.
CCC UUU
Displays time/date and user number for each arming and
disarming of the system for the partition selected.
CCC UUU
Displays time/date for system problems, such as AC loss,
communication failure, etc., regardless of partition.
CCC UUU
Installer or Master Code + [#] + [6] + [0]
Installer or Master Code + [#] + [6] + [1]
Installer or Master Code + [#] + [6] + [2]
Press [
] at any time.
Section 16 – Event Log Options