Summary Of Connections - ADEMCO VISTA-128B Installation And Setup Gude

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-128B:
Table of Contents

Advertisement

WARNING: OWNER'S INSTRUCTION NOTICE NOT TO BE REMOVED
1. Zone 1 may be selected for EOLR supervised
NOTES:
or normally closed (no EOLR) operation via
cut jumper. (Cut red jumper for normally closed
operation. Do not cut for Fire Usage). Zones 2-8
Blue
may be selected for either operation via program
Jumper
field *41.
(note 5)
2.
Zone 1 supports 2-wire smoke detectors.
See Installation Instructions for recommended type
and maximum number of detectors supported.
BATTERY
TABS
3.
Zone 7 may be used for remote keyswitch arming/disarming.
See Installation Instructions for wiring instructions.
Connect to
12VDC, 4AH
or 12VDC, 7AH
1
2
3
4
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.7VDC
See
Connect to
Installation
24hr. 120VAC,
Instructions for
60 Hz Outlet
required
capacity
Replace
every
TRANSFORMER
3 years
16.5VAC, 40VA
ADEMCO No.1361
(IN CANADA
USE No. 1361CN)
or 4300 IF
X-10 DEVICES
+
BELL
WILL BE USED
+
-
AUXILARY POWER OUTPUT
NOTE:
9.6VDC - 13.8VDC,
WHEN POWERING UP
750mA maximum
THE PANEL, PLUG THE
Note: Include current drawn
TRANSFORMER IN BEFORE
by keypads and polling loop
CONNECTING THE BATTERY.
devices when making
SIREN
auxiliary power calculations.
ALARM SOUNDER OUTPUT 10VDC - 13.8VDC
Notes For UL Household Fire Installations
1. Use 12VDC, 14AH battery
2. Maximum auxiliary current,
including polling loop 300mA
3. Combined alarm and auxilary power output
and polling loop current must be limited to 750mA
for UL985 Household Fire Installations.
4.
Zone 8 supports 2-wire latching type glass break detectors.
See Installation Instructions for recommended type and
maximum number of detectors supported.
5. Cut blue jumper to disable supervision of alarm sounder output.
Leave jumper intact to supervise output. (See Installation
Instructions for Programming and Wiring Instructions).
Red Jumper
(note 1)
ZONE 2 ZONE 3
5
6
7
8
9
10
11
12
ZONE 1
+
+
-
N.C.
Red
Blk
Grn
Yel
REMOTE KEYPAD
Use 4137AD/6137/6128
N.O.
5137AD/6139
(Addressable keypads) only
2k EOLR
See Installation Instructions
(note 1)
for max # of keypads
and for max wire run length.
+
-
Fire
-
Usage
SMOKE
N.C.
Burg.
Usage
N.O.
Zone resistance (Excluding EOLR):
ZONE 1,8: 100 OHMS MAXIMUM
2k EOLR
ALL OTHER ZONES: 300 OHMS MAXIMUM
(note 1,2)
Zone response time:
ZONES 1-8: 350mSec-500mSec
ZONE 9: Programmable for
ALL CIRCUITS ARE
POWER LIMITED.

SUMMARY OF CONNECTIONS

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.
J7 Header
J8 Header
1. Not Used
1. In 2 (Printer DTR)
2. Ground
2. Ground-
3. Out 1 (Ground Start)
3. In 3 (4300 sync)
4. Ground-
4. In 4 (4300 sync)
5. Out 2 (fire)
5. Ground
6. Out 5 (4300 data)
6. Ground-
7. Out 6 (Printer RXD)
7. Out 3 (burg/aud. panic)
8. Ground
8. Ground
9. Ground
9. Out 4 (silent panic/
duress)
(Refer to Installation Instructions for information concerning Direct Wire
Downloading and printer connections using the 4100SM Serial Module.)
ZONE 4 ZONE 5
ZONE 6 ZONE 7
13
14
15
16
17
18
19
20
+
+
+
-
-
N.C.
N.C.
N.C.
N.O.
N.O.
N.O.
2k EOLR
2k EOLR
2k EOLR
(note 1)
(note 1)
(note 1,3)
+
+
-
GLASS
BREAK
N.C.
N.C.
N.C.
N.O.
N.O.
N.O.
2k EOLR
2k EOLR
2k EOLR
(note 1)
(note 1)
(note 1,4)
Polling loop rating: 128mA max. See
Installation Instructions for maximum
number of devices supported and
maximum wire run length
Fast: 10mSec-15mSec
Normal: 350mSec-500mSec
(default response)
VISTA-128B
Optional programming:
Out 1: Open/close or keypad-like sounding
Out 2: Armed LED
Out 4: Ready LED
Ratings for Out 1:
Active: 10VDC-13.8VDC through 4k OHMS
Not Active: 100 OHMS to ground
Ratings for out 2-4:
Active: 10VDC-13.8VDC through 5k OHMS
Not Active: 1k OHMS to ground
ZONE 8 ZONE 9
21
22
23
24
25
26
28
27
+
-
Handset
Incoming
Phone Line
Telephone connections
using Ademco No. 620
RJ31X direct connect
cord.
THIS EQUIPMENT SHOULD BE INSTALLED
+
-
+
IN ACCORDANCE WITH THE NATIONAL
4190
FIRE PROTECTION ASSOCIATION'S
RPM
STANDARD 72 (NATIONAL FIRE
PROTECTION ASSOC., BATTERYMARCH
4192SD
PARK. QUINCY, MA. 02269). PRINTED
N.C.
SMOKE
INFORMATION DESCRIBING PROPER
INSTALLATION, OPERATION, TESTING,
4278
N.C.
MAINTENANCE, EVACUATION PLANNING
PIR
AND REPAIR SERVICE IS TO BE
PROVIDED WITH THIS EQUIPMENT.
USE UL LISTED ENERGY CABLE FOR ALL CONNECTIONS
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B
CONNECTION OF THE FIRE ALARM SIGNAL
THIS DEVICE COMPLIES WITH PART 15 OF
TO A FIRE ALARM HEADQUARTERS OR A
FCC RULES. OPERATION IS SUBJECT TO THE
CENTRAL STATION SHALL BE PERMITED
FOLLOWING TWO CONDITIONS: (1) THIS DEVICE
ONLY WITH THE APPROVAL OF THE LOCAL
AUTHORITY HAVING JURISDICTION. THE
MAY NOT CAUSE HARMFUL INTERFERENCE, AND
BURGLAR ALARM SIGNAL SHALL NOT BE
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
CONNECTED TO A POLICE EMERGENCY
RECEIVED, INCLUDING INTERFERENCE
NUMBER.
THAT MAY CAUSE UNDESIRED OPERATION.
MAKE CONNECTIONS USING
No. 4142TR CABLE
J8
1 2 3 4 5 6 7 8 9
J7
1 2 3 4 5 6 7 8 9
EARTH GROUND
Connect to good earth
29
30
ground to maintain im-
munity to transients.
See Instructions for
proper grounding.
DOC LOAD NO.: 5
WARNING: TO PREVENT
RISK OF ELECTRICAL
SHOCK, DISCONNECT
TELCO JACK BEFORE
SERVICING THIS PANEL.